How do you charge 410a - The Refrigerant Pump-Down Method. Yes, this is in fact, true and it's called the refrigerant pump-down method. Whenever a new condensing unit is purchased it is pre-charged at the factory with refrigerant. Most are precharged for a line set up to 25 feet. The refrigerant is released by opening two valves, one for the liquid line (liquid line ...

 
Before discussing the R-410A recovery process it is impor-tant to address safety. The major difference between R-22 and R-410A is the significantly higher pressures involved with using R-410A. Working with R-410A requires some additional tools that you may not already have in your service vehicle. The pressure-temperature chart for R-410A compares. Stop the flow of blood crossword

ing. Solder joints must be bare and clean. Do not clean the pipe connections with emery paper as this. leaves traces on the soft surface of the copper. Solder flows best on smooth surfaces. To clean the copper pipes use steel wool or a cleaning fleece. Ensure that solder joints are made only using safety gas.Remove the cap to the low pressure line (Usually the only port). Check the gauges and be sure the valves are turned off (clockwise). Connect the gauges center yellow hose to the R410a refrigerant tank. Connect the adapter to the blue low pressure line on the gauges. As quickly as possible, attach the blue hose with the adapter to the mini split ...Well, you can't charge to the high side. It should be obvious that the output of the compressor is going to be a higher pressure than the R-410a in the bottle at ambient temp. I have never done R-410a yet but as I understand it you charge liquid to the low side but *slowly* as to allow it to vaporize on the way in so it doesn't slug the compressor.As an example, the required charge is forty-five percent less when compared to R-134a and sixty percent less when compared to R-12. Lastly, isobutane is relatively low cost when compared to the synthetic refrigerants we use today. Cons. Well, you may have guessed it by now, but the biggest drawback when it comes to R-600a is it’s flammability ...Wrap the thermometer bulb in wet cloth and then measure the wet bulb temperature the same way as the dry bulb measurement, recording the results. This is …Do you want to learn how to charge your mini split with 410a refrigerant? Watch this video and follow the instructions to get the job done. You will also find a link to buy the refrigerant online ...New container with 1.8 lbs of Pro Charge R410A Refrigerant pre-blended with with UV Dye & Leak Sealant. Intended for use by qualified technician only. Gauges are not included with purchase and are available sold separately. USE ONLY IN A/C SYSTEMS ORIGINALLY DESIGNED FOR REFRIGERANT R410A. DO NOT MIX WITH ANY OTHER …R-466A was developed to replace R-410A in larger charge (>1 pound per unit) residential HVAC applications. Depending on the system design, the charge size will be 10-15% higher than R-410A, said LaPietra, but the procedures for charging will be similar to other Class 1 refrigerants such as R-410A. At this stage, R-466A is intended for new ...24 posts · Joined 2010. #6 · Jan 14, 2011 (Edited) The amount for factory charge for 15 ft. should be listed somewhere on the condenser, Possibly inside the controls cover plate in ounces. I have a goodman 2.5 ton R410a heatpump and the recommended amount to add over 15ft. is (number of feet over 15 times .6 ounces) Note: the actual ...Post Likes. I charge by subcooling, jump the fan cycle/outdoor temp swt. to get all condenser fan motors going. disable unloaders, hgbp etc to get the unit loaded 100% then add refrigerant till 5 degrees of subcooling are reached. depending on the fan cycle settings the subcool would go up to 20+ degrees when the fans are not running but drop ...R410-A condensers, I've been installing many, many 3 ton 410-A condensers over the course of the past few weeks, are approximately $60 less than dry charged condensers and they come charged. I picked up a jug of 410-A for $59, buy a condenser and get a jug for that price. $98.00 if alone. R-22 iss $364 alone. Lennox.Jan 26, 2024 · When you conduct leak inspections on appliances that contain 50 or more pounds of ozone-depleting refrigerant, you must provide the customer with documentation that includes the date of inspection; the method(s) used to conduct the leak inspection; a list of the location(s) of each leak that was identified; and a certification that all visible ... Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R-22 and R-410A...Superheat Charging. To charge a system using superheat, you will need to monitor the actual temperature of the low-pressure suction line, the saturation temperature of the low side suction gauge, and the indoor and outdoor temperatures entering the unit(s).. Most, if not all, manufacturers have a charging chart available with their respective units. With the information you have gathered on ...The charge is pretty standard, I've seen anywhere between $15-$20 for 609 testing. Again, this test can be done in person with your employer, community college, or a trade school. Certification Study Guides. ... (R-410A, R-404A, & R-134A are excluded from this.) This helps us keep compliant and prevents any and all future headaches for you or ...Adding Freon to heat pump during the heat mode, Carrier Unit, winter season maintenance, 2018 HVAC TECHNICIANAdding Freon to heat pump during the heat mode, Carrier Unit, winter season maintenance, 2018 HVAC TECHNICIANHey guys. So they say to only charge 410a as a liquid. Scenario: guy at at work recovers 5.8lbs of 410a into vacuumed recovery cylinder. Then, in order to get only …MikeDobbs said: I have a Fujitsu mini split system which needs a little 410a refrigerant added to it. This particular unit has a very small leak, and needed a top off about 3 years after it was installed. It's now about 3 years after that, and it's not putting out very cold air. The wait to get an AC tech out to the house is several weeks right ...This is how to check the charge on an outdoor condenser using the subcooling process. We take the Saturation temperature found on the high side of the gauge ...R410a has several advantages over other refrigerants. It is more efficient and can cool or heat a space more effectively using less energy. It is also less flammable at ambient temperatures and less likely to contribute to ozone depletion. Additionally, R410a is a non-toxic refrigerant, so it is generally safe to use in homes and businesses.™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems ... The information set forth herein is furnished free of charge and based on technical data that Chemours believes to be reliable. It is intended for use by persons having technical skill ...In this HVAC Training Video, I show How to Add R-410A into a Running Air Conditioner that is Very Low on Refrigerant. I Show the Step by Step Procedure for C...Robert Lee of Testo shows you the important steps in charging an AC system with the testo 550 Digital Manifold.Learn more about the Testo 550 Digital Manifol...This is How to Check the Refrigerant Charge on a System Without a TXV that has a Piston/Orifice or Capillary Metering Device in front of the Evaporator Coil....Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig.It is free of ozone-depleting gasses chlorine or bromine as it is mainly made of fluorine, making it a safer, cleaner, and legal alternative. For those of you based in regions where the heat wave can get to 90 to 100 degrees in the summer, be ready to spend around $3-$8 for a pound of r-410a Freon. Since the r-410a is an absolute necessity for ...Get it up to 200 and it would be grossly overcharged. It will be likely running in the 35 to 45f degree saturation (boiling point) range, 108 to 131 psi. The high side has an even greater range. The pressures will vary as the operating conditions like return air temperature, outdoor temperature change."In addition, R-454B has the lowest global warming potential of the R-410A alternatives being discussed today, and equipment designed for R-454B requires less charge than today's R-410A systems." It is important to note that as a mildly flammable refrigerant, R-454B cannot be retrofitted into existing R-410A or R-22 systems.Robert Lee of Testo shows you the important steps in charging an AC system with the testo 550 Digital Manifold.Learn more about the Testo 550 Digital Manifol...AC MINI SPLIT QUICK CHARGE R410Amerch = https://teespring.com/stores/steve-lavhttps://www.patreon.com/stevenlavimonierelavimoniere productions llcsubscribe ...Take the following steps. To recharge the refrigerant in your air conditioner, first shut down your AC unit, then follow the steps below: 2. Attach the hoses from the gauge manifold to your system's pressure ports. The low pressure hose is normally blue and is connected to the suction line—the larger of the two pipes.The clamp-on thermometer reads 77°F. Here is how we use the subcooling formula to manually calculate the subcooling in this system: Subcooling (R-22) = 89°F - 77°F = 12°F. We see that the calculated subcooling for R-22 refrigerant in this system is 12°F. This is the manual calculation.In this HVAC Training Video, I Show If You Can Check The Refrigerant Charge on an Inverter Mini-Split Ductless Unit on a Service Call by measuring superheat ...The maximum recommended temperature is often around 150 to 160 degrees Fahrenheit (65.6 to 71.1°C) for the condenser coil. What is normal subcooling for 410A? Normal subcooling for R-410A systems can range from 10 to 20 degrees Fahrenheit (5.6 to 11.1°C) depending on the specific system design and conditions.The authors report that 10% of the residential heat pumps they surveyed had detectable leaks and that 3.8% of the total refrigerant charge was lost annually. Catastrophic leaks, in which systems lost 50% or more of their initial charge, were responsible for the vast majority—about 92%—of refrigerant losses. Heat pumps, properly installed ...With the regulatory phase-out of R22, the HVAC sought out an alternative refrigerant that prioritizes environmental friendliness and energy efficiency. One such substitute that has gained widespread acceptance is R410A, a hydrofluorocarbon (HFC) blend. Unlike R22, R410A does not contribute to ozone depletion and has a lower GWP.I charged it by weight, and after letting it run a few hours, the unit stabilized at 100 psi on the low with a 36 degree evap cover off and 31 sat. Giving 5 ...An essential tool for charging 410A by subcooling is a set of HVAC gauges. These gauges allow you to measure the pressure in your system, helping you determine the correct refrigerant charge. Make sure to use gauges specifically designed for use with 410A refrigerant.More efficient. R32 has higher cooling efficiency, making it more energy efficient than R410A. More cost effective. Less R32 is required than R410A and it is easy to handle making refilling cost lower. R-32 can reduce electricity consumption by up to 10%. Better for the environment.Adding Freon to heat pump during the heat mode, Carrier Unit, winter season maintenance, 2018 HVAC TECHNICIANReplacement Options: If you noticed, both of these R-410A compressor's capacity ratings at 45°/130° are just over 25,000 btu/hr (2-tons). But because of their types of mechanical compression, along with the system condition compression ratios, we know that this affects the volumetric efficiency. As defined in part two of this series ...If you need to remove R-22 or R-410A from a system, you must recover the refrigerant based on EPA criteria. Never vent it into the atmosphere! When charging an R-410A system, you must charge from the refrigerant cylinder in the liquid form (pull the liquid from the canister in the upside-down position), and charge into the low side of the system.Take the following steps. To recharge the refrigerant in your air conditioner, first shut down your AC unit, then follow the steps below: 2. Attach the hoses from the gauge manifold to your system's pressure ports. The low pressure hose is normally blue and is connected to the suction line—the larger of the two pipes.Adjust Refrigerant Charge. If your subcooling value is outside the target range, adjust the refrigerant charge as necessary. If subcooling is too low, add refrigerant; if subcooling is …In this HVAC Training Video, I Show How to Check the Charge and Add R-410A Refrigerant on an Air Conditioner that is Low. I Show the Procedure for Connection...Outstanding Features Perfect for topping off a system or to add a small amount of refrigerant. Just connect charging hose to can and charging service port and press button. The gauge can be re-used. Kit includes 1 disposable tank of R410a 1.8lb, 1 gauge with color base scale to check, push button to recharge unit.410A does have to be captured, has near zero odp (ozone depletion potential) but very high gwp (global warming potential). You can't just release the whole charge into atmosphere. With that being said, changing out a reversing valve is the hardest job in the field in my opinion.Ferguson HVAC is a national distributor of residential and commercial heating and cooling equipment, parts and supplies. HVAC contractors across the country rely on us for the best unitary and ductless equipment brands and for a wide-range of HVAC products including accessories, controls, air distribution supplies, and service and repair parts.Both are HFC refrigerants. They have zero ozone depletion potential. Major differences are: R32 is a single component refrigerant while R410A is a zeotropic blend. R32 has a lower boiling point (-52.5 0 C) than R410A (-48.5 0 C) R32 has a global warming potential of 675 while R410A has a GWP of 2088. R410A will no longer be in use after 2025 ...How much refrigerant do you charge? Connect the red hose of the manifold gauge to the high side valve on the back of the condenser and charge a 410A condensing unit. Connect the 410A refrigerant tank to the yellow hose on the manifold gauge. Make sure the air conditioner is turned on. Allow the 410A refrigerant to enter the system by turning ...Mar 19, 2021 ... Comments127 ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips! AC Service Tech LLC · 1.3M views ; How to purge bleed ...The Mini Split R410A Recharge Kit is perfect for topping off a system or to add a small amount of refrigerant. Just connect charging hose to can and adapter to charging service port and press button. Gauge can be re-used. Includes 28.2oz R410A can, gauge and hose, and 5/16' to 1/4' service port adapter.Yes they do. Also, 410a is about to get goneeee very soon anyway. Starting 1/1/24, new chillers can't come with 134a, 407c or 410a. Residential is right behind it but isn't official yet. ... If you have to charge that much for the refrigerant you probably need to assess what and why you are charging for your other services.New container with 1.8 lbs of Pro Charge R410A Refrigerant pre-blended with with UV Dye & Leak Sealant. Intended for use by qualified technician only. Gauges are not included with purchase and are available sold separately. USE ONLY IN A/C SYSTEMS ORIGINALLY DESIGNED FOR REFRIGERANT R410A. DO NOT MIX WITH ANY OTHER REFRIGERANT.4. if "x" is below outdoor temperature line, add charge and repeat 3. 5. if "x" is above outdoor temperature line, recover excess charge and repeat 3. 6. pressures are ref. only -final charge varification to be based on "design subcooling" note at the top of the cooling chart. charge chart (60 hz) 7-1/2 ton split system heat pump 92 ...Part 2-This is How to Charge an R-410A System that is very LOW on Refrigerant first with a Saturation Temperature of the evaporator coil so that it doesn't F...UPDATED MANIFOLD: Gauge sets used with R-410A should be okay to use with R-454B, although technicians may need to update their digital manifolds to include the newer refrigerants. (Staff Photo) March 16, 2021. Refrigerant regulations are changing quickly at the state and federal levels, in order to facilitate a smooth transition away from R ...On average, R-410A costs $125 for a 25-pound cylinder. This means that the R-410A works out at $5 per pound. However, this is the cost of R-410A when it is supplied to license holders who are 608 certified. If you are not an HVAC specialist, then you are unlikely to be able to buy R-410A yourself and instead will have to purchase it via an …This Shows you (in Real-Time) How to Charge R-410A Refrigerant into a System that is Low on Cha... Charging R-410A Refrigerant into a Unit that has King Valves! This Shows you (in Real-Time) How ...In Today's video, I am charging gas or refrigerant in an inverter ac mini-split unit, which is R-410a gas. It's a complete procedure in which we have told yo...Step by step tutorial. Full video tutorial and recharging of refrigerant.Troubleshooting and charging refrigerant 410a for CARRIER CRYSTAL split type aircon ...No, you cannot. To make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system. Putting them together would be like putting two cats in a box and sending them ...Superheat Charging. To charge a system using superheat, you will need to monitor the actual temperature of the low-pressure suction line, the saturation temperature of the low side suction gauge, and the indoor and outdoor temperatures entering the unit(s).. Most, if not all, manufacturers have a charging chart available with their respective units. …Connect the yellow hose on the manifold gauge to the 410A refrigerant tank. Turn the handle on top of the tank to release refrigerant from the tank. Flip the tank upside down so that it will charge the system in a liquid state.Jun 7, 2016 · This is a Step by Step Process (In Real-time) of Adding R-410A Refrigerant into a System that is a little Undercharged! We use the Subcooling Process to show you how far the Charge is off and Exactly what we need to do to Add Refrigerant and How to Verify that we have the Correct Charge once we are complete. Support- Tool List- Is your iPhone not charging? If you find yourself constantly struggling with this issue, don’t fret. There could be a number of reasons why your beloved device is not getting the p...The cost of R-410A freon is $125 per 25-pound cylinder, which equals out to be $5.00 per pound. The average home uses 2 to 4 pounds of R-410A per ton of your air conditioning unit. So, if your unit is 3 tons, and you use three pounds per ton, you'll need 9 pounds of R-410A. The thing with R-410A freon is that it only comes in 25-pound ...The charge is pretty standard, I've seen anywhere between $15-$20 for 609 testing. Again, this test can be done in person with your employer, community college, or a trade school. Certification Study Guides. ... (R-410A, R-404A, & R-134A are excluded from this.) This helps us keep compliant and prevents any and all future headaches for you or ...R-410A refrigerant must be removed from the drum in a liquid state. If you are charging it into the low side of the system, remember...Specifications subject to change without notice.421 01 5501 05 4/10/18. INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioners. NXA4/6 N4A3/4/5/6 R4A3/4/5 WCA3/4/5/6. These instructions must be read and understood completely before attempting installation. IMPORTANT:Effective January 1, 2015, all split system and packaged air ...The gauge is color coded in green so you know how much refrigerant to add and this information is included in the instructions we have provided! (1) SPECIAL, R410a, COLOR CODED, "CHECK & CHARGE-IT" Gauge. (1) CPS AD87 R410a adapter Fitting (1) 36" Charging Hose (1) Instructions on R410a systems.In this HVAC Training Video, I show How to Add R-410A into a Running Air Conditioner that is Very Low on Refrigerant. I Show the Step by Step Procedure for C...410A refrigerant (ASHRAE designation: R-410A [50/50]), have been developed and are presented here. These tables are based on extensive experimental measurements. Equations have been developed, based on the Martin-Hou equation of state, which represent the data with accuracy and consistency throughout the entire range ofcharging multizone mini split unit. hello, got a question. i have a multi zone mini split unit that currently doesnt have any r410 in it. i would like to charge it to factory charge. currently i have only only 1 zone connected to it. Can i charge the unit through one of the unused ports or do i charge it the the port where i have lineset connected?system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.R-410A is an HFC refrigerant that is a blend of the HFC R-32 and the HFC R-125. This refrigerant was designed to be a safe, non-toxic, non-flammable, and reliable alternative to the HCFC R-22. It was invented in 1991 but did not begin to see real popularity until the 2000’s. What is Puron?Jul 7, 2019 · Charging a A/C system by subcooling. Determine your target subcooling. This is usually displayed on the back of the nameplate, located on your condensing unit. If not, 10-15 degrees F will get you ballpark range. With the unit running, connect your high side refrigerant gauge, to the liquid line port, or fitting. When connecting gauges, connect to the always-suction port on the low side. On quite a few systems, you can get your head pressure on the liquid line, but some systems may require you to connect to the discharge line to check the head pressure. A common rule of thumb is the 100-degrees over ambient rule; the temperature of the discharge line on ... Charging R-410A Refrigerant: Step By Step Process of Adding Refrigerant in Real-Time!This is a Step by Step Process (In Real-time) of Adding R-410A Refrigera... So, for a 3-ton system, you’d need around 0.9 to 1.2 pounds of R410A. How do you calculate refrigerant charge? Refrigerant charge is typically calculated based on the manufacturer’s guidelines, which take into account factors like the type of refrigerant, system size, line set length, and other specific system parameters.In this HVACR Training Video, I show How to Use the SMAN460 Digital Manifold Gauge Set with Temperature Clamps to Check the Refrigerant Charge on an Air Cond...More efficient. R32 has higher cooling efficiency, making it more energy efficient than R410A. More cost effective. Less R32 is required than R410A and it is easy to handle making refilling cost lower. R-32 can reduce electricity consumption by up to 10%. Better for the environment.R-410A systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves ...Amazon is going to start charging delivery fees for Fresh grocery orders that are under $150, the company said in an email to Prime members. Amazon is going to start charging deliv...Yes, an individual can buy R-410A refrigerant, but there are some limitations. By law, only those who have taken and passed the EPA 608 exam can buy any refrigerant, but there are many sellers on eBay who seem to have a workaround. Many listings on eBay will send R410A refrigerant as long as a message is signed saying that the refrigerant is ...This video shows how to check a refrigerant charge on an ac unit. This goes over how to use the gauge set, temperature sensor, saturation temperature, and ac...R-404A is fine to top off after a leak. If you have lost a huge percentage of your charge, there may be some fractionation, but even then the new refrigerant you would be adding back would end up being the majority of the system charge, so no problems. Reply. 08-30-2013, 07:18 PM #6. jtrammel.Outstanding Features Perfect for topping off a system or to add a small amount of refrigerant. Just connect charging hose to can and charging service port and press button. The gauge can be re-used. Kit includes 1 disposable tank of R410a 1.8lb, 1 gauge with color base scale to check, push button to recharge unit.All my favorite HVAC tools: https://www.amazon.com/shop/thediyhvacguy?ref=ac_inf_tb_vhFollow us for more diy hvac tips & to enter for our giveaways!Instagram...When charging a refrigeration system, there are five main rules to follow: Rule 1. Always charge a receiver/sight glass/TXV system under a high evaporator heat load. This could mean simply opening the doors or putting an artificial or false heat load on the evaporator. Rule 2.

As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of .... 2021 silverado 6 speed transmission problems

how do you charge 410a

From $9.41. R22 R410A Air Conditioning Charging Adapter For 1/4\" Safety Valve.Sep 1, 2023 · Remove the plastic sheeting and replace the low-voltage wire. If the pump operates correctly, you can now set it back to heating mode. The superheat method helps to charge a heat pump in temperatures as low as 20F. However, there are more accurate methods such as charging by weight and charging by discharge temperature. All my favorite HVAC tools: https://www.amazon.com/shop/thediyhvacguy?ref=ac_inf_tb_vhFollow us for more diy hvac tips & to enter for our giveaways!Instagram...R410a freon replacement costs around $260, on average, and most homeowners pay between $140 and $380, depending on the quantity and location. R -410A refrigerant costs anywhere from about $140 to $380 per 25-pound container. Costs rise in the summer when the demand for indoor cooling surges. To replace R-410A refrigerant, you can expect to pay ...R-22, R-410A Refrigerants! Checking the Charge- How to tell if there is a Restriction or Bad TXV!This is how to figure out if a TXV is not letting enough Ref...Add on product: Recharge kit with gauge and hose $29.95. Now with a new shut-off valve standard ¼ " SAE. R410A 2 lb. FREE SHIPPING NATIONWIDE (CONTINENTAL US) 100% VIRGIN FACTORY SEALED. GUARANTEED PRODUCT QUALITY. Ability Refrigerant stocks a large store of R22, R410A, MO99, 407C, 404A and R134A. VIEW SAFETY DATA SHEET.Robert Lee of Testo shows you the important steps in charging an AC system with the testo 550 Digital Manifold.Learn more about the Testo 550 Digital Manifol...R410a freon replacement costs around $260, on average, and most homeowners pay between $140 and $380, depending on the quantity and location. R -410A refrigerant costs anywhere from about $140 to $380 per 25-pound container. Costs rise in the summer when the demand for indoor cooling surges. To replace R-410A refrigerant, you can expect to pay ...This is How to Check the Refrigerant Charge on a System Without a TXV that has a Piston/Orifice or Capillary Metering Device in front of the Evaporator Coil....AC MINI SPLIT QUICK CHARGE R410Amerch = https://teespring.com/stores/steve-lavhttps://www.patreon.com/stevenlavimonierelavimoniere productions llcsubscribe ...July 12, 2023. Robert Scaringe, PE, Ph.D. Refrigeration. Flushing Techniques For R-22 to R-410A Conversions. Dec. 1, 2007. Many contractors are experiencing compressor burnout problems with R-410A HVACR systems soon after they’re converted from R-22 refrigerant. A conversion should always include condenser, …Since R-410A acts very much like a single component refrigerant, any change in composition due to a leak is minimal. The system can be topped off, without removing the entire charge. There is no practical limit to the number of times a unit can be topped-off or the refrigerant recovered from a unit.The HVAC industry and regulations have more or less made the decision for you. R-410A is the better of the two, both for an efficient system and for helping the environment. When you go to purchase a new system, make sure you get one with R-410A rather than a dry charging system. Feel free to call us with any questions.November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ...Add on product: Recharge kit with gauge and hose $29.95. Now with a new shut-off valve standard ¼ " SAE. R410A 2 lb. FREE SHIPPING NATIONWIDE (CONTINENTAL US) 100% VIRGIN FACTORY SEALED. GUARANTEED PRODUCT QUALITY. Ability Refrigerant stocks a large store of R22, R410A, MO99, 407C, 404A and R134A. VIEW SAFETY DATA SHEET..